Error codes for air conditioners Bork (Bork) - decoding and instructions

Error codes for air conditioners Bork (Bork) - decoding and instructionsWhen a breakdown is detected by the system, error codes of Bork air conditioners are displayed on the front panel of the outdoor unit. The codes are combinations of flashing and illuminated multi-colored LEDs.

Decoding the error of air conditioners BorkError code air conditioner Bork Diode 1Diode 2Diode 3
Air conditioner error Bork Violation of the rise and fall of pressureblinksblinksBlinking
Cooling refrigerant in warm mode—Lights upLights up
Excess compressor temperatureLights up—Lights up
System voltage too low—Lights up—
Bork air conditioner error: engine speed is correctedLights upLights upLights up
Outdoor unit overload protection is enabled—Lights upBlinking

If the compressor does not turn on, the LEDs of the outdoor unit show the following error codes for Bork air conditioners

Decoding the error of the air conditioner BorkDiode 1Diode 2Diode 3
Works fine———
Short circuit on the room temperature sensor——Lights up
Short circuit of the temperature sensor of the internal heat exchanger—Lights up—
Errors of air conditioners Bork: Short circuit of the compressor temperature sensorLights up——
The function of the temperature sensor of the external heat exchanger is brokenLights up—Lights up
The function of the outside air temperature sensor is brokenLights upLights up—
Power supply interruptedBlinkingLights up—
The power supply to the outdoor unit is interruptedBlinking—Lights up
No communication between indoor and outdoor units——Blinking
Overvoltage protection enabled—Blinking—
Errors of air conditioners Bork: Maximum current controlLights upBlinkingLights up
Equipment shutdown due to overloadLights upBlinking—
Compressor temperature exceeded—BlinkingLights up
Indoor and outdoor unit current monitoring has shut down the systemLights upLights upBlinking
Ambient air temperature higher or lower than planned by the manufacturerLights upBlinkingBlinking
Refrigerant leakBlinkingLights upLights up
Compressor overheating—Lights upBlinking
Incorrect operation of the outdoor unitLights upLights upLights up
Incorrect operation of the engine of the indoor unit—BlinkingBlinking
Violated communication with the control board—Lights upLights up
The compressor has stopped due to an errorBlinking—Blinking
Fan breakageBlinkingBlinkingLights up
Outdoor compressor overheatedLights upBlinkingLights up

In order to start the self-diagnosis function, press the POWER button four times in ten seconds and the error codes of the Bork air conditioner will be displayed on the display.